1.
Int. j. morphol ; 41(1): 111-117, feb. 2023. ilus, tab
Article in English | LILACS | ID: biblio-1430506

ABSTRACT

SUMMARY: Anatomical variation of the foramina transversaria (FT) is associated with vertebral neurovascular symptoms and can cause complications after lower spine surgery, especially cervical pedicle screw (CPS) insertion. FT variation has been documented and classified in various populations, as this information can help increase cervical stability in subaxial vertebral surgery. Although the morphometry of the upper cervical spine in Thai populations has been reported, there have yet been no studies examining the features of FT. The FT of dried cervical spines (C3-C7; left and right side; n = 107, male = 53 and female = 54) were examined for morphological variation, and their anteroposterior (AP) and transverse (T) diameters were measured using a digital vernier caliper. Morphometric data and variations were compared by sex and lateral side. It was that the C3-C6 FT in both sexes were round, and the C7 FT was elliptical with an oblique right side. FT diameters did not differ significantly by sex except for the AP diameters of C6-C7 and for T diameters of C4 and C7. The left AP diameters of C3-C6 were significantly longer than the right, as were the T diameters of C4 and C7 FT. Additionally, T diameter was significantly longer than that of the AP, except that of the left C6 in male spines, which did not differ from the AP. Most FT examined were round. These findings should be considered in the provisional diagnosis of vertebral neurovascular symptoms caused by FT variation as well as that of neurovascular damage after cervical pedicle screw placement.


La variación anatómica del foramen transverso (FT) se asocia con síntomas neurovasculares vertebrales y puede causar complicaciones después de la cirugía de columna cervical inferior, especialmente la inserción de tornillos pediculares cervicales (TPC). La variación del FT se ha documentado y clasificado en varias poblaciones, ya que esta información puede ayudar a aumentar la estabilidad cervical en la cirugía vertebral subaxial. Aunque se ha informado sobre la morfometría de la columna cervical superior en poblaciones tailandesas, aún no se han realizado estudios que examinen las características de FT. Se examinó la variación morfológica del FT de vértebras cervicales secas (C3-C7; lado izquierdo y derecho; n = 107, hombres = 53 y mujeres = 54), y se midieron sus diámetros anteroposterior (AP) y transverso (T) usando un pie de metro digital. Se compararon datos morfométricos y variaciones por sexo y lado. Los FT de C3-a C6 en ambos sexos eran redondos, y el FT C7 era elíptico con el lado derecho oblicuo. Los diámetros del FT no difirieron significativamente por sexo excepto para los diámetros AP de C6- C7 y para los diámetros transversos de C4 y C7. Los diámetros AP izquierdos de C3-C6 eran significativamente más largos que los del lado derecho, al igual que los diámetros transversos de C4 y C7. Además, el diámetro transverso fue significativamente mayor que el AP, excepto el C6 izquierdo en las vértebras de hombres, que no difirió del AP. La mayoría de los FT examinados eran redondos. Estos hallazgos deben ser considerados en el diagnóstico provisional de síntomas neurovasculares vertebrales causados por la variación del FT, así como en el de daño neurovascular tras la colocación de tornillos pediculares cervicales.


Subject(s)
Humans , Male , Female , Cervical Vertebrae/anatomy & histology , Anatomic Variation , Thailand , Sex Characteristics
2.
Chinese Journal of Orthopaedic Trauma ; (12): 427-432, 2023.
Article in Chinese | WPRIM | ID: wpr-992729

ABSTRACT

Objective:To investigate the effect of the use of medial calcar screws on the treatment of Neer type Ⅲ proximal humeral fracture with Multiloc intramedullary nailing.Methods:A retrospective study was conducted to analyze the data of 36 patients with Near type Ⅲ fracture of the proximal humerus who had received Multiloc intramedullary nailing at Department of Upper Limbs, Sichuan Orthopedic Hospital from January 2016 to December 2021. There were 6 males and 30 females with an age of (63.9±5.3) years. They were divided into 2 groups according to whether medial calcar screws had been used or not. There were 17 cases in the group without medial calcar screws and 19 cases in the group with medial calcar screws. The 2 groups were compared in terms of flexion and lifting, external rotation, internal rotation and back touch, visual analogue scale (VAS), American Shoulder and Elbow Surgeons (ASES) score, Constant-Murley score for shoulder function (Constant score), neck shaft angle, and incidence of complications at the last follow-up.Results:There were no statistically significant significances in the preoperative general data between the 2 groups, indicating comparability between the groups ( P>0.05). The 36 patients were followed up for 13.5(12.0,19.8) months after surgery. The flexion and lifting, external rotation, internal rotation and back touch, VAS, ASES score, Constant score, neck shaft angle at the last follow-up in the group without medial calcar screws were, respectively, 134.1°±8.4°, 32.1°±5.3°, 14.0 (13.0, 15.5) , 0.0 (0.0, 1.0), 78.2±5.2, 78.0±5.8, and 137.6°±8.1°, insignificantly different from those in the group with medial calcar screws [134.7°±6.1°, 35.0(30.0, 35.0)°, 14.0(13.0, 15.0), 1.0 (0.0, 1.0), 78.2±5.4, 76.7±4.5, and 136.9°±6.4°] ( P>0.05). Postoperative complications occurred in 6 patients in each group, showing no statistically significant difference between the 2 groups ( P=1.000). Conclusion:The use of medial calcar screws has no significant impact on the postoperative shoulder function and incidence of complications in the treatment of Neer type Ⅲ fractures of the proximal humerus with Multiloc intramedullary nailing.

3.
Chinese Journal of Orthopaedic Trauma ; (12): 37-42, 2023.
Article in Chinese | WPRIM | ID: wpr-992678

ABSTRACT

Objective:To evaluate the feasibility of using cortical bone trajectory (CBT) screws in the osteoporotic thoracolumbar fixation by comparing the bone CT values at the bone-screw interface between traditional trajectory (TT) screws and CBT screws in patients with different bone densities.Methods:The high-resolution CT imaging data of thoracolumbar segments following thoracic or lumbar spine fractures from April 2020 to October 2022 were collected at The Second Hospital Affiliated to Wenzhou Medical University for retrospective analysis. They were divided into 3 groups: a normal bone mass group, an osteopenia group and an osteoporosis group. From each group 30 cases were chosen (90 cases in total, 36 males and 54 females). All the data were imported into Mimics 18.0 for three-dimensional bone reconstruction in which placement of TT and CBT screws was simulated on the vertebrae from T10 to L2 (non-fractured vertebrae). Regions of interest (ROI) where each simulated screw intersected the bone were segmented to measure their CT bone values. For each vertebra in each group, the relative difference percentage in average CT value of ROI between TT and CBT screws was calculated. The CT values of ROI were compared in the same group between TT and CBT screws from T10 to L2; the CT values of ROI were compared in the same screws among the 3 groups from T10 to L2; the CT values of ROI were compared between the CBT screws in the osteopenia and osteoporosis groups and the TT screws in the normal bone mass group; the relative difference percentages in average CT value of ROI between CBT and TT screws were compared between the 3 groups from T10 to L2.Results:The average CT value of ROI for CBT screws was significantly higher than that for TT screws from T10 to L2 in every group ( P< 0.001); as for the CT values of ROI for CBT and TT screws from T10 to L2, the osteoporosis group<the osteopenia group<the normal bone mass group ( P<0.001); from T10 to L2, the CT value of ROI for CBT screws in the osteopenia group was significantly higher than that for TT screws in the normal bone mass group ( P<0.001); the CT value of ROI for CBT screws in the osteoporosis group was not significantly different from that for TT screws in the normal bone mass group ( P>0.05). At T10, T12, and L1, the relative difference percentage in average CT value of ROI between CBT and TT screws was significantly higher in the osteopenia and osteoporosis groups than that in the normal bone mass group ( P<0.05), but there was no such a difference between the osteopenia and the osteoporosis groups ( P>0.05). At T11 and L2, there was no significant difference between the 3 groups in the relative difference percentage in average CT value of ROI between CBT and TT screws ( P>0.05). Conclusions:As bone mass decreases, both CBT and TT screws lead to a significant decrease in the bone density at the bone-screw interface. In patients with osteoporosis, CBT screws can still lead to a higher bone density at the bone-screw interface than TT screws, thus providing a higher strength at the bone-screw interface.

4.
Chinese Journal of Trauma ; (12): 341-348, 2023.
Article in Chinese | WPRIM | ID: wpr-992607

ABSTRACT

Objective:To compare the effect of O-arm assisted and free-hand pedicle screw placement in the treatment of AO type C thoracolumbar fracture.Methods:A retrospective cohort study was used to analyze the clinical data of 34 patients with type C thoracolumbar fracture admitted to Henan Provincial People′s Hospital from January 2018 to June 2021, including 23 males and 11 females; aged 42-63 years [(50.4±7.4)years]. The fracture was located at T 11 in 4 patients, T 12 in 10, L 1 in 12, L 2 in 6, T 11~12/L 1 in 1 and T 12/L 1 in 1. Posterior reduction and internal fixation was carried out for all patients, of whom 18 were treated with O-arm assisted pedicle screw placement (navigation group) and 16 with free-hand pedicle screw placement (free-hand group). The operation time, single screw placement time, intraoperative bleeding volume, operation mode and screw placement accuracy were compared between the two groups. The kyphotic Cobb angle, visual analogue score (VAS) and American Spinal Injury Association (ASIA) score were compared between the two groups before operation, at 1 week after operation, at 3 months after operation and at the last follow-up. Postoperative complications were observed. Results:All patients were followed up for 12-29 months [(16.8±6.1)months]. There was no significant difference between the two groups in the operation time, intraoperative bleeding volume and operation mode (all P>0.05). The single screw placement time was (9.4±1.6)minutes in navigation group, but was (10.8±1.5)minutes in free-hand group ( P<0.05). The screw placement accuracy was 97.4% in navigation group, but was 81.5% in free-hand group ( P<0.01). The kyphotic Cobb angle and VAS had no significant differences between the two groups before operation (all P>0.05). The kyphotic Cobb angle in navigation group and free-hand group was (4.3±1.1)° and (5.9±1.1)° at 1 week after operation, (4.4±1.2)° and (5.7±1.3)° at 3 months after operation, and (4.4±1.2)° and (6.8±0.9)° at the last follow-up, decreased significantly from that before operation [(21.8±3.1)°, (22.2±3.2)°] (all P<0.01). The kyphotic Cobb angle in navigation group was significantly lower than that in free-hand group at 1 week, 3 months after operation and at the last follow-up (all P<0.01). The VAS in navigation group and free-hand group was (3.2±0.7)points and (4.1±0.7)points at 1 week after operation, (2.4±0.6)points and (3.0±0.8)points at 3 months after operation, and (1.8±0.9)points and (2.6±0.7)points at the last follow-up, decreased significantly from that before operation [(8.4±0.8)points, (8.3±0.9)points] (all P<0.01). The VAS in navigation group was significantly lower than that in free-hand group at 1 week, 3 months after operation and at the last follow-up (all P<0.01). The ASIA score showed no significant difference within and between the two groups before operation, at 1 week, 3 months after operation and at the last follow-up (all P>0.05). Postoperative incision infection occurred in 1 patient in both groups ( P>0.05). Implant failure such as loosening or displacement was not observed in navigation group, and only occurred in 2 patients in free-hand group ( P>0.05). Conclusion:Compared with free-hand pedicle screw placement, O-arm assisted pedicle screw placement in the treatment of AO type C thoracolumbar fracture has advantages of rapid and accurate screw placement, good reduction and notable pain relief.

5.
Journal of Medical Biomechanics ; (6): E110-E115, 2023.
Article in Chinese | WPRIM | ID: wpr-987922

ABSTRACT

Objective To study biomechanical effects of cannulated screws at different fixation angles on posterior malleolus fracture based on finite element method, so as to determine the best fixation method of cannulatedscrew. Methods The finite element model of ankle joint, including tibia, fibula, astragalus, corresponding cartilage and ligaments was reconstructed using CT images, and 1 / 2 posterior malleolus fracture model was established on the basis of verifying its validity. The biomechanical effects of cannulated screw fixation on posterior malleolus fracture fixation model were analyzed. Results Compared with 0°,5°,10°,20° fixation model, the 15° fixation model had the smallest displacement. The screw stress of 15° fixation model was lower than that of 5°, 10°, 20° fixation model, and higher than that of 0° fixation model. But when the screw fixation angle was 0°, the peak contact pressure of ankle joint was much larger than that of normal ankle joint, which was easy to cause traumatic osteoarthritis. Conclusions Cannulated screw is safe and effective for treating posterior malleolus fracture which is less than 1 / 2 fragment size. The displacement and stress of the model are different at different fixation angles of screws. When the fixation angle of screw is 15°, the biomechanical stability is the best, which can be used to guide clinical operation.

6.
Journal of Medical Biomechanics ; (6): E037-E044, 2023.
Article in Chinese | WPRIM | ID: wpr-987911

ABSTRACT

Objective To investigate biomechanical differences of two posterior occipitocervical internal fixation techniques for treating basilar invagination with atlantoaxial dislocation (BI-AAD). Methods Intra-articular cage + posterior occipital plate+C2 pedicle screw (Cage+C2PS+OP), and intra-articular cage+C1 lateral mass screw+C2PS (Cage+C1LMS+C2PS) models were established based on occipitocervical CT data of the BI-AAD and clinical operation scheme, and the stability of atlantoaxial joint and stress distribution characteristics of C2 endplate and implanted instruments under different motion states were analyzed. Results Compared with the Cage+C1LMS+C2PS model, the atlantoaxial range of motion ( ROM) under flexion, extension, lateral bending and axial rotation in the Cage+C2PS+OP model were reduced by 5. 26% , 33. 33% , 43. 75% , -5. 56% , and stress peak of screw-rod fixation system were reduced by 47. 81% , 60. 90% , 48. 45% , 39. 14% , respectively. Under two internal fixation modes, stresses of C2 endplate and cage were mainly distributed on the compressive side during the motion, and both the screw-bone interface and the caudal side of screw subjected to large loading. Conclusions Two internal fixation methods could provide similar stability. However, the stress concentration of screw-rod system was more obvious and the possibility of screw loosening and fracture was greater under Cage+ C1LMS+C2PS fixation.

7.
Journal of Medical Biomechanics ; (6): E030-E036, 2023.
Article in Chinese | WPRIM | ID: wpr-987910

ABSTRACT

Objective To compare the effects of cortical bone trajectory ( CBT) and traditional trajectory ( TT)pedicle screw internal fixation on the range of motion (ROM) and rod system stress of normal and osteoporotic(OP) spines. Methods The L3-S1 finite element models of normal and OP spines were established. The screwrod system with two kinds of trajectory was used for internal fixation of the L4-5 segment, so as to simulate sixphysiological loads, namely, flexion, extension, left / right bending, left / right rotation. The effects of two internalfixation methods on ROMs and maximum equivalent stress of screws in normal and OP spines were compared.Results For both bone conditions, CBT and TT significantly reduced ROM of the fixed segment (L4-5) and theentire segment of lower lumbar spine ( L3-S1). However, the ROM decline of CBT group was slightly smaller than that of TT group, and their ROMs were similar under flexion and extension, but the ROM differences were significant under lateral bending and axial rotation. In addition, for both the normal and OP spine models, themaximum equivalent stress of screws in CBT group was significantly higher than that in TT group. Compared withTT group, the screw stress of CBT group in normal spine model under flexion and extension, lateral bending,axial rotation was increased by 27% , 268% and 58% , respectively. However, when CBT technique was used atthe same time, the OP spine model had a smaller screw stress distribution than the normal spine model.Conclusions Compared with TT technique, CBT technique can achieve higher screw stress under OP conditionand reduce screw stress concentration under normal bone condition. In addition, CBT slightly increases ROMs of each segment, which is conducive to recovery of spinal physiological function after surgery. Lateral bending and axial rotation can produce negative mechanical effects, and these two physiological loads should be avoided.

8.
Journal of Peking University(Health Sciences) ; (6): 530-536, 2023.
Article in Chinese | WPRIM | ID: wpr-986885

ABSTRACT

OBJECTIVE@#To investigate the effectiveness of percutaneous pedicle screw fixation combined expandable tubular retractor in the treatment of patients with spinal metastases.@*METHODS@#In the study, 12 patients of spinal metastases treated with percutaneous pedicle screw fixation combined expandable tubular retractor in our hospital were retrospectively reviewed between June 2017 and October 2019. Among the 12 patients, 9 were males and 3 were females; the median age was 62.5 years [(65.1±2.9) years]. The decompression segment of 7 patients was located at the lower thoracic spine (including 1 patient with incomplete paraplegia) and the decompression segment of 5 patients was located at the lumbar spine; Tomita score was 6.0±0.6. Perioperative data of the patients were reviewed. Visual analog scale (VAS score), Karnofsky score, and Eastern Cooperative Oncology Group (ECOG) score were compared before and after surgery. The patient's survival, adjuvant treatment, and internal fixation failure were observed in the follow-up period.@*RESULTS@#All the 12 patients had a successful operation with percuta-neous pedicle screw fixation combined expandable tubular retractor. The average operative time, blood loss, and blood transfused of the patients were (247.0±14.6) min, (804.2±222.3) mL and (500.0±100.0) mL, respectively. The average amount of drainage was (240.8±79.3) mL. Drainage tubes were pulled out early postoperative [(3.2±0.3) d], allowing early mobilization. The patients discharged (7.8±0.8) d postoperative. All the patients were followed up for 6-30 months, and the average overall survival time was (13.6±2.4) months. During the follow-up period, 2 patients experienced screw displacement, the internal fixation was stable after conservative treatment and no revision surgery was performed. The VAS of the patients was 7.1±0.2 before surgery, which decreased to 2.3±0.1 and 2.8±0.4 at 3 and 6 months after surgery (P < 0.05). The Karnofsky score of the patients was 59.2±1.9 before surgery, which increased to 75.0±1.9 and 74.2±3.1 at 3 and 6 months after surgery (P < 0.05). The ECOG of the patients was 2.3±0.2 before surgery, which decreased to 1.7±0.1 and 1.7±0.2 at 3 and 6 months after surgery (P < 0.05).@*CONCLUSION@#For selected patients with spinal metastases, minimally invasive surgical treatment of spinal metastases (percutaneous pedicle screw internal fixation combined with expandable tubular retractor) can effectively relieve the clinical symptoms and improve the quality of life, with satisfactory clinical outcome.


Subject(s)
Male , Female , Humans , Middle Aged , Pedicle Screws , Treatment Outcome , Spinal Neoplasms/surgery , Quality of Life , Retrospective Studies , Fracture Fixation, Internal , Lumbar Vertebrae/surgery , Thoracic Vertebrae/surgery , Spinal Fusion , Spinal Fractures/surgery
9.
China Journal of Orthopaedics and Traumatology ; (12): 450-453, 2023.
Article in Chinese | WPRIM | ID: wpr-986787

ABSTRACT

OBJECTIVE@#According to the characteristics of spinal burst fractures in high-altitude areas and the local medical conditions, to explore the clinical efficacy of short-segment fixation with pedicle screws combined with screw placement in injured vertebrae in the treatment of thoracolumbar burst fractures.@*METHODS@#From August 2018 to December 2021, 12 patients with single-vertebral thoracolumbar burst fractures without neurological symptoms were treated with injured vertebral screw placement technique, including 7 males and 5 females;aged 29 to 54 years old, with an average of(42.50±7.95) years old;6 cases of traffic accident injury, 4 cases of high fall injury, 2 cases of heavy object injury;2 cases of T11, 4 cases of T12, 3 cases of L1, 2 cases of L2, and 1 case of L3. In the operation, screws were first placed in the upper and lower vertebrae of the fracture, pedicle screws were placed in the injured vertebra, and connecting rods were installed, and the fractured vertebral body was reset by positioning and distraction. Visual analogue scale (VAS) and Japanese Orthopedic Association (JOA) scoring were used to evaluate the changes in pain and quality of life of patients, and the kyphotic correction rate and correction loss rate of the injured segment were measured by X-ray.@*RESULTS@#All operations were successful without significant intraoperative complications. All 12 patients were followed up, the duration ranged from 9 to 27 months, with an mean of (17.75±5.79) months. VAS at 3 days after operation was significantly higher than that at admission (t=6.701, P=0.000). There was significant difference in JOA score between 9 months after operation and at admission (t=5.085, P=0.000). Three days after operation, Cobb angle was (4.42±1.16)°, and the correction rate was (82±5)% compared with (25.67±5.71)° at admission. Cobb angle was (5.08±1.24) °at 9 months after operation, with a corrected loss rate of (16±13)%. No loosening or breakage of internal fixation was found.@*CONCLUSION@#Under the high-altitude hypobaric and hypoxic environment, the effect of the operation should be ensured while reducing the trauma. The application of the technique of placing screws on the injured vertebra can effectively restore and maintain the height of the injured vertebra, with less bleeding and shorter fixed segments, which is an effective method.


Subject(s)
Male , Female , Humans , Adult , Middle Aged , Pedicle Screws , Altitude , Quality of Life , Lumbar Vertebrae/injuries , Thoracic Vertebrae/injuries , Spinal Fractures/surgery , Fracture Fixation, Internal/methods , Fractures, Compression , Treatment Outcome , Fractures, Comminuted
10.
China Journal of Orthopaedics and Traumatology ; (12): 262-267, 2023.
Article in Chinese | WPRIM | ID: wpr-970859

ABSTRACT

OBJECTIVE@#With the help of finite element analysis, to explore the effect of proximal humeral bone cement enhanced screw plate fixation on the stability of internal fixation of osteoporotic proximal humeral fracture.@*METHODS@#The digital model of unstable proximal humeral fracture with metaphyseal bone defect was made, and the finite element models of proximal humeral fracture bone cement enhanced screw plate fixation and common screw plate fixation were established respectively. The stress of cancellous bone around the screw, the overall stiffness, the maximum stress of the plate and the maximum stress of the screw were analyzed.@*RESULTS@#The maximum stresses of cancellous bone around 6 screws at the head of proximal humeral with bone cement enhanced screw plate fixation were 1.07 MPa for No.1 nail, 0.43 MPa for No.2 nail, 1.16 MPa for No.3 nail, 0.34 MPa for No.4 nail, 1.99 MPa for No.5 nail and 1.57 MPa for No.6 nail. These with common screw plate fixation were:2.68 MPa for No.1 nail, 0.67 MPa for No.2 nail, 4.37 MPa for No.3 nail, 0.75 MPa for No.4 nail, 3.30 MPa for No.5 nail and 2.47 MPa for No.6 nail. Overall stiffness of the two models is 448 N/mm for bone cement structure and 434 N/mm for common structure. The maximum stress of plate appears in the joint hole:701MPa for bone cement structure and 42 0MPa for common structure. The maximum stress of screws appeared at the tail end of No.4 nail:284 MPa for bone cement structure and 240.8 MPa for common structure.@*CONCLUSION@#Through finite element analysis, it is proved that the proximal humerus bone cement enhanced screw plate fixation of osteoporotic proximal humeral fracture can effectively reduce the stress of cancellous bone around the screw and enhance the initial stability after fracture operation, thus preventing from penetrating out and humeral head collapsing.


Subject(s)
Humans , Finite Element Analysis , Bone Cements , Polymethyl Methacrylate , Biomechanical Phenomena , Shoulder Fractures/surgery , Fracture Fixation, Internal , Humeral Head , Bone Screws , Bone Plates
11.
China Journal of Orthopaedics and Traumatology ; (12): 226-231, 2023.
Article in Chinese | WPRIM | ID: wpr-970852

ABSTRACT

OBJECTIVE@#To compare the efficacy of percutaneous compression plate and cannulated compression screw in the treatment of displaced femoral neck fractures in young and middle-aged patients.@*METHODS@#From January 2015 to July 2020, 68 young and middle-aged patients with displaced femoral neck fracture were retrospectively analyzed. Among them, 31 cases were fixed by percutaneous compression plate (PCCP), and 37 cases were fixed by cannulated compression screw (CCS). General data such as gender, age, cause of injury, comorbidities, fracture classification and cause of injury of two groups were collected. The operation time, intraoperative blood loss, hospital stay, full weight bearing time, fracture healing time, visual analogue scale(VAS), Harris hip score and complications were compared between two groups.@*RESULTS@#Patients in both groups were followed up for more than 2 years. There were no significant differences in operation time, intraoperative blood loss, fracture reduction quality, hospital stay and VAS between two groups. The fracture healing time in PCCP group was significantly shorter than that in CCS group (t=-4.404, P=0.000). The complete weight bearing time of PCCP group was significantly shorter than that of CCS group (t=-9.011, P=0.000). Harris score of hip joint in PCCP group was better than that in CCS group 2 years after operation (P=0.002). Complications occurred in 3 cases (9.68%) in PCCP group, while 11 cases (29.72%) in CCS group, with a statistically significant difference (P=0.042).@*CONCLUSION@#Both PCCP and CCS can be used for the treatment of displaced femoral neck fractures in young and middle-aged people. Compared with CCS, PCCP fixation can achieve shorter fracture healing time and create conditions for early full weight bearing. PCCP results in higher hip score and lower complications.


Subject(s)
Middle Aged , Humans , Treatment Outcome , Blood Loss, Surgical , Retrospective Studies , Fracture Fixation, Internal/methods , Femoral Neck Fractures/surgery , Bone Screws
12.
China Journal of Orthopaedics and Traumatology ; (12): 221-225, 2023.
Article in Chinese | WPRIM | ID: wpr-970851

ABSTRACT

OBJECTIVE@#To investigate the clinical efficacy and advantages of Tianji orthopedic robot assisted cannulated screw internal fixation for femoral neck fracture.@*METHODS@#The clinical data of 41 patients with femoral neck fracture who underwent internal fixation with cannulated screws from January 2019 to January 2022 were retrospectively analyzed. According to different surgical methods, they were divided into Tianji robot group and traditional cannulated screw fixation group (traditional operation group). Among them, there were 18 patients in Tianji robot group including 8 males and 10 females with age of (56.00±4.22) years old, Garden typeⅠ (4 cases), type Ⅱ (11 cases), type Ⅲ (2 cases), and type Ⅳ (1 case). There were 23 patients in the traditional operation group, including 10 males and 13 females, aged (54.87±4.81) years old;there were 5 cases of Garden typeⅠ, 14 cases of type Ⅱ, 3 cases of type Ⅲ and 1 case of type Ⅳ. The operation time, intraoperative blood loss, fluoroscopy times, guide needle placement times, operation costs and other indicators were observed and compared between two groups. Harris score was used to evaluate hip joint function 12 months after operation.@*RESULTS@#The wounds of all patients healed in Grade A without complications. There were significant differences between two groups in terms of operation time, times of intraoperative fluoroscopy, times of guide needle placement, amount of intraoperative bleeding, and operation cost (P<0.05). All 41 patients were followed up for at least 12 months. The fractures of both groups were healed. There was no infection, screw loosening, fracture displacement and femoral head necrosis in Tianji robot group during follow-up;Screw loosening occurred in 2 patients in the traditional operation group during follow-up. At 12 months after operation, Harris hip joint function score of Tianji robot group was higher than that of traditional operation group in daily activity, lameness, joint activity score and total score (P<0.05).@*CONCLUSION@#Tianji robot assisted nail placement is a better method for the treatment of femoral neck fracture, which improves the surgical efficiency, is more accurate, has higher success rate of one-time nail placement, shorter operation time, less radiation, and has better hip joint function recovery after surgery.


Subject(s)
Male , Female , Humans , Middle Aged , Robotics , Retrospective Studies , Femoral Neck Fractures/surgery , Bone Screws , Fracture Fixation, Internal/methods , Treatment Outcome
13.
China Journal of Orthopaedics and Traumatology ; (12): 209-215, 2023.
Article in Chinese | WPRIM | ID: wpr-970849

ABSTRACT

OBJECTIVE@#To investigate the application of 3D printing percutaneous surgical guide plate in closed reduction and cannulated screw internal fixation of femoral neck fracture.@*METHODS@#The clinical data of 12 patients with femoral neck fracture from March 2019 to March 2022 were retrospectively analyzed. Patients were divided into observation group and control group according to different operation plans, with 6 cases in each group. The observation group received percutaneous operation guide plate assisted closed reduction and hollow screw internal fixation, while the control group received closed reduction and hollow compression screw internal fixation. The operation time, intraoperative blood loss, fluoroscopy times, and Kirschner needle puncture times were compared between two groups. The location of screws were recordedon postoperative X-ray films, follow-up time, time of complete fracture healing, Harris score of hip joint and the incidence of complications were recorded on postoperative X-ray films.@*RESULTS@#The operation time of observation group (32.17±6.18) min was shorter than that of control group (53.83±7.31) min (P<0.05). The amount of intraoperative bleeding in the observation group (18.33±2.94) ml was less than that in the control group (38.17±5.56) ml(P<0.05). The times of fluoroscopy in the observation group (7.50±1.05) were less than those in the control group (21.00±4.82) (P<0.05). The number of Kirschner needle punctures (8.00±0.63) in observation group was less than that in control group (32.67±3.08) (P<0.05). The follow-up time was(12.88±0.74) months in observation group and (12.83±0.72) months in control group, there was no significant difference between two groups (P>0.05). One year after operation, Harris score of hip joint in the observation group was(82.00±4.52) points, while that in the control group was(81.00±3.41) points, there was no significant difference between two groups(P>0.05). The time of complete fracture healing in the observation group was (7.50±1.05) months, while that in the control group was (7.67±1.21) months, there was no significant difference between two groups(P>0.05). The parallelism of the screws in the observation group was (0.50±0.11) ° and (0.76±0.15) °, which were lower than that in the control group (1.57±0.31) ° and (1.87±0.21) ° (P<0.05). The screw distribution area ratio (0.13±0.02) cm2 in the observation group was higher than that in the control group (0.08±0.01) cm2 (P<0.05). No complications such as necrosis of femoral head, nonunion of fracture, shortening of femoral neck and withdrawal of internal fixation occurred in both groups.@*CONCLUSION@#The application of 3D printing percutaneous surgical guide plate improves the accuracy and safety of closed reduction and cannulated screw internal fixation for femoral neck fracture. It has the advantages of minimally invasive, reducing radiation exposure, fast and accurate, shortening the operation time and reducing intraoperative bleeding.


Subject(s)
Humans , Retrospective Studies , Treatment Outcome , Femoral Neck Fractures/surgery , Fracture Fixation, Internal , Bone Screws , Printing, Three-Dimensional
14.
STOMATOLOGY ; (12): 24-27, 2023.
Article in Chinese | WPRIM | ID: wpr-965112

ABSTRACT

@#In the complications of dental implant treatment, the mechanical complications, such as central screw breakage, are often complex and serious. This article analyzes factors that affect the loosening of the central screw. Understanding relevant risk factors can prompt doctors to take corresponding strategies to reduce the possibility of complications in clinical operations. After encountering broken cases, this paper also gives some ideas and methods of treatment, and finally summarizes clinical suggestions for preventing the central screw fracture.

15.
China Journal of Orthopaedics and Traumatology ; (12): 635-640, 2023.
Article in Chinese | WPRIM | ID: wpr-981747

ABSTRACT

OBJECTIVE@#To investigate the clinical efficacy of femoral neck system(FNS) and three cannulated compression screws(CCS) in the treatment of unstable femoral neck fractures in young adults.@*METHODS@#The clinical data of 52 young and middle-aged patients with unstable femoral neck fractures admitted from August 2018 to August 2021 were reviewed and analyzed. All patients were divided into two groups according to the internal fixation method, 25 cases were treated with FNS fixation, 27 cases were treated with closed reduction and 3 CCS inverted triangular distribution. The operation time, incision length, intraoperative bleeding, hospitalization expenses and fracture reduction quality of two groups were recorded and compared;The patients were followed up regularly after operation. The fracture healing time, complete weight-bearing time and postoperative complications(nonunion, femoral neck shortening, femoral head necrosis) of two groups were compared. The Harris score was used to evaluate hip function 6 months after surgery.@*RESULTS@#The operation was successfully completed in both groups. The patients in FNS group had more bleeding, longer incision length and higher hospitalization cost than CCS group(P<0.01). There ware no significant difference in operation time and Garden index between two groups(P>0.05). Patients in both groups were followed up for 6 to 32 months.The fracture healing time in FNS group was less than that in CCS group, the time of complete weight bearing after surgery was earlier than that in CCS group, and the hip Harris score was higher than that in CCS group (P<0.01). There were no internal fixation fracture complications in two groups during follow-up. In the FNS group, there were 4 cases of avascular necrosis of the femoral head and 2 cases of femoral neck shortening, of which 3 cases underwent total hip replacement due to avascular necrosis of the femoral head. In the CCS group, there were 2 cases of nonunion, 9 cases of avascular necrosis of the femoral head, and 11 cases of femoral neck shortening, among which 5 cases underwent total hip replacement due to nonunion and avascular necrosis of the femoral head.@*CONCLUSION@#With simple operation, rotational stability and angular stability, FNS enables patients to start functional exercise as early as possible and reduces the incidence of postoperative complications of unstable femoral neck fracture. It is a new choice for the treatment of unstable femoral neck fracture in young adults.

16.
China Journal of Orthopaedics and Traumatology ; (12): 487-489, 2023.
Article in Chinese | WPRIM | ID: wpr-981719

ABSTRACT

OBJECTIVE@#To explore the technical aspects of the accuracy of cervical pedicle screw placement with O-arm guidance.@*METHODS@#The clinical data of 21 patients who underwent cervical pedicle screw fixation by O-arm real-time guidance from December 2015 to January 2020 were analyzed retrospectively. There were 15 males and 6 females, aged from 29 to 76 years old with an average of (45.3±11.5) years. The postoperative CT scan was utilized to evaluate the placement of the pedicle screw and classified according to the Gertzbein and Robbins classification.@*RESULTS@#A total of 132 pedicle screws were implanted in 21 patients, 116 at C3-C6 and 16 at C1 and C2. According to Gertzbein & Robbins classification, the overall breach rates were found to be 11.36% (15/132) with 73.33% (11 screws) Grade B, 26.67% (4 screws) Grade C, and no Grade D or E screw breaches. There were no pedicle screw placement related complications at final follow-up.@*CONCLUSION@#The application of O-arm real-time guidance technology can make cervical pedicle screw placement reliable. High accuracy and better intra-operative control can increase surgeon's confidence in using cervical pedicle instrumentation. Considering the high-risk nature of anatomical area around cervical pedicle and the possibility of catastrophic complications, the spine surgeon should have sufficient surgical skills, experience, ensures stringent verification of the system, and never relies solely on the navigation system.


Subject(s)
Male , Female , Humans , Adult , Middle Aged , Aged , Retrospective Studies , Imaging, Three-Dimensional , Surgery, Computer-Assisted , Tomography, X-Ray Computed , Pedicle Screws , Spinal Fusion
17.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 572-577, 2023.
Article in Chinese | WPRIM | ID: wpr-981634

ABSTRACT

OBJECTIVE@#To compare the effectiveness of open reduction of posterior cruciate ligament (PCL) avulsion fracture at tibial insertion of knee joint with absorbable screws fixation and absorbable screw combined with suture anchor fixation.@*METHODS@#The clinical data of 26 patients with PCL avulsion fracture at tibial insertion who met the selection criteria between March 2015 and October 2021 were retrospectively analyzed. Among them, 14 patients were fixed with simple absorbable screw (group A), and 12 patients were fixed with absorbable screw combined with suture anchors (group B). All patients were confirmed by X-ray film, CT, or MRI preoperatively, and got positive results in preoperative posterior drawer tests. There was no significant difference in gender, age, side of affected limb, time from injury to operation, comorbidities, and preoperative Meyers & McKeever classification, Lysholm score, and International Knee Documentation Committee (IKDC) score between the two groups ( P>0.05). The operation time and postoperative complications were recorded and compared between the two groups. At last follow-up, Lysholm score and IKDC score were used to evaluate the improvement of knee function.@*RESULTS@#There was no significant difference in operation time between the two groups ( P>0.05). All incisions healed by first intention, and no complication such as vascular and nerve injury or venous thrombosis occurred. All 26 patients were followed up 9-89 months, with an average of 55.3 months. The follow-up time of group A and group B was (55.7±23.2) and (56.8±29.3) months, respectively, with no significant difference ( t=-0.106, P=0.916). Radiographs showed bone healing in both groups at 3 months after operation, and no complication such as infection and traumatic arthritis occurred. At last follow-up, the posterior drawer test was negative in both groups, and the Lysholm score and IKDC score significantly improved when compared with the pre-operative values ( P<0.05). However, there was no significant difference in the improvement value between the two groups ( P>0.05).@*CONCLUSION@#For PCL avulsion fracture at tibial insertion of the knee joint, the open reduction and absorbable screw combined with suture anchor fixation can achieve reliable fracture reduction and fixation, which is conducive to the early rehabilitation and functional exercise, and the postoperative functional recovery of the knee joint is satisfactory.


Subject(s)
Humans , Posterior Cruciate Ligament/injuries , Suture Anchors , Fractures, Avulsion/surgery , Retrospective Studies , Tibial Fractures/surgery , Arthroscopy/methods , Fracture Fixation, Internal/methods , Knee Joint/surgery , Bone Screws , Suture Techniques , Treatment Outcome
18.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 438-442, 2023.
Article in Chinese | WPRIM | ID: wpr-981611

ABSTRACT

OBJECTIVE@#To explore the percutaneous hollow screw internal fixation combined with cementoplasty in the treatment of periacetabular metastasis.@*METHODS@#A retrospective study was performed on 16 patients with periacetabular metastasis who were treated with percutaneous hollow screw internal fixation combined with cementoplasty between May 2020 and May 2021. There were 9 males and 7 females. The age ranged from 40 to 73 years, with an average of 53.6 years. The tumor involved around the acetabulum, and 6 cases were located on the left and 10 cases on the right. Operation time, frequency of fluoroscopy, bed rest time, and complications were recorded. Before operation, and at 1 weeks, 3 months after operation, the visual analogue scale (VAS) score was used to evaluate the pain degree, the short-form 36 health survey scale (SF-36) score was used to evaluate the quality of life. At 3 months after operation, the Musculoskeletal Tumor Society (MSTS) scoring system was used to evaluate the functional recovery of patients. During follow-up, the loosening of internal fixator and bone cement leakage were observed by X-ray film.@*RESULTS@#All patients were performed operation successfully. The operation time ranged from 57 to 82 minutes, with an average of 70.4 minutes. The frequency of intraoperative fluoroscopy was 16-34 times, with an average of 23.1 times. After operation, 1 case of incision hematoma and 1 case of scrotal edema occurred. All patients felt the pain relieved after operation. The patients started walking at 1-3 days after operation, with an average of 1.4 days. All patients were followed up 6-12 months (mean 9.7 months). The VAS and SF-36 scores significantly improved after operation when compared with the preoperative scores, and the scores at 3 months after operation were significant better than those at 1 week after operation ( P<0.05). At 3 months after operation, the MSTS score ranged from 9 to 27, with an average of 19.8. Among them, 3 cases were excellent (18.75%), 8 cases were good (50%), 3 cases were fair (18.75%), and 2 cases were poor (12.5%). The excellent and good rate was 68.75%. And 11 patients returned to normal walking, 3 had mild claudication, and 2 had obvious claudication. Radiological examination showed that there were 2 cases of bone cement leakage after operation, and there was no internal fixator loosening or displacement.@*CONCLUSION@#Percutaneous hollow screw internal fixation combined with cementoplasty can effectively relieve pain and improve the quality of life of patients with periacetabular metastasis.


Subject(s)
Male , Female , Humans , Adult , Middle Aged , Aged , Spinal Fractures/surgery , Retrospective Studies , Bone Cements , Quality of Life , Treatment Outcome , Fracture Fixation, Internal , Bone Screws , Cementoplasty , Pain
19.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 431-437, 2023.
Article in Chinese | WPRIM | ID: wpr-981610

ABSTRACT

OBJECTIVE@#To investigate the surgical technique and effectiveness of titanium elastic nail (TEN) assisted retrograde channel screw implantation of superior pubic branch.@*METHODS@#The clinical data of 31 patients with pelvic or acetabular fractures treated with retrograde channel screw implantation in superior pubic branch between January 2021 and April 2022 were retrospectively analyzed. Among them, 16 cases were implanted with assistance of TEN (study group) and 15 cases were implanted under the guidance of C-arm X-ray machine (control group). There was no significant difference in gender, age, cause of injury, Tile classification of pelvic fracture, Judet-Letournal classification of acetabular fracture, and time from injury to operation between the two groups ( P>0.05). The operation time, fluoroscopy times, and intraoperative blood loss of each superior pubic branch retrograde channel screw were recorded during operation. X-ray films and three-dimensional CT were reexamined after operation, the quality of fracture reduction was evaluated by Matta score standard, and the position of channel screw was evaluated by screw position classification standard. The fracture healing time was recorded during the follow-up, and the postoperative functional recovery was evaluated by Merle D'Aubigne Postel score system at last follow-up.@*RESULTS@#Nineteen and 20 retrograde channel screws of superior pubic branch were implanted in the study group and the control group, respectively. The operation time, fluoroscopy times, and intraoperative blood loss of each screw in the study group were significantly less than those in the control group ( P<0.05). According to the postoperative X-ray films and three-dimensional CT, none of the 19 screws in the study group penetrated out of the cortical bone or into the joint, and the excellent and good rate was 100% (19/19); in the control group, there were 4 screws of cortical bone penetration, and the excellent and good rate was 80% (16/20); the difference between the two groups was significant ( P<0.05). Matta score standard was used to evaluate the quality of fracture reduction, there was no patient in the two groups with poor reduction results, and the difference was not significant between the two groups ( P>0.05). The incisions of the two groups healed by first intention, and there was no complication such as incision infection, skin margin necrosis, and deep infection. All patients were followed up 8-22 months, with an average of 14.7 months. There was no significant difference in healing time between the two groups ( P>0.05). At last follow-up, the difference in functional recovery evaluated by the Merle D'Aubigne Postel scoring system between the two groups was not significant ( P>0.05).@*CONCLUSION@#TEN assisted implantation technique can significantly shorten the operation time of retrograde channel screw implantation of superior pubic branch, reduce the times of fluoroscopy, and have less intraoperative blood loss and accurate screw implantation, which provides a new safe and reliable method for minimally invasive treatment of pelvic and acetabular fractures.


Subject(s)
Humans , Titanium , Fracture Fixation, Internal/methods , Blood Loss, Surgical , Retrospective Studies , Bone Screws , Treatment Outcome , Fractures, Bone/surgery , Spinal Fractures , Hip Fractures
20.
Chinese Journal of Traumatology ; (6): 48-59, 2023.
Article in English | WPRIM | ID: wpr-970966

ABSTRACT

PURPOSE@#Combined anterior and posterior ring (APR) fixation is classically performed in Tile B2 and C1 injuries to achieve superior biomechanical stability. However, the posterior ring (PR) is the main weight bearing portion that is responsible for weight transmission from the upper parts of the body to the lower limbs through the sacrum and the linea terminalis. It is hypothesized that isolated PR fixation can achieve comparable radiological and clinical outcomes to APR fixation. Therefore, we conducted this study to compare the two fixation principles in managing Tile B2 and C1 injuries.@*METHODS@#Our study included 20 patients with Tile B2 injuries and 20 patients with Tile C1 injuries. This study was a randomized control single-blinded study via computerized random numbers with a 1:1 allocation by using random block method. The study was performed at a level one trauma center. A total of 40 patients with Tile B2 and C1 injuries underwent combined APR or isolated PR fixation (Group A and B, respectively). Matta & Tornetta radiological principles and Majeed pelvic scoring system were used for the assessment of primary outcomes and postoperative complications. Secondary outcomes included operative time, amount of blood loss, intraoperative assessment of reduction, need of another operation, length of hospital stay, ability to weight bear postoperatively and pain control metrics. We used student t-test to compare the difference in means between two groups, and Chi-square test to compare proportions between two qualitative parameters. We set the confidence interval to 95% and the margin of error accepted to 5%. So, p ≤ 0.05 was considered statistically significant.@*RESULTS@#The mean follow-up duration was 18 months. The operative time (mean difference 0.575 h) and the intraoperative blood loss (mean difference 97.5 mL) were lower in Group B. Also, despite the higher frequency of rami displacement before union in the same group, there were no significant differences in terms of radiological outcome (excellent outcome with OR = 2.357), clinical outcome (excellent outcome with OR = 2.852) and postoperative complications assessment (OR = 1.556) at last follow-up.@*CONCLUSION@#The authors concluded that isolated PR fixation could favorably manage Tile B2 and C1 pelvic ring injuries with Nakatani zone II pubic rami fractures and intact inguinal ligament. Its final radiological and clinical outcomes and postoperative complications were comparable to combined APR fixation, but with less morbidity (shorter operation time, lower amount of blood, and no records of postoperative wound infection).


Subject(s)
Humans , Fracture Fixation, Internal/methods , Pelvic Bones/injuries , Bone Screws , Retrospective Studies , Fractures, Bone/surgery , Spinal Fractures , Treatment Outcome